T1 - Hydraulic micro device with force sensing for measurement of mechanical characteristics
AU - Sasaki, Tohru
AU - Fujiwara, Yudai
AU - Tachikawa, Kaoru
AU - Terabayashi, Kenji
AU - Dohda, Kuniaki
N1 - Publisher Copyright:
© 2020, Fuji Technology Press. All rights reserved.
PY - 2020
Y1 - 2020
N2 - The medical and bio-engineering fields have been increasingly using information and communication technology. To introduce robots into surgical procedures, data on surgical operations are required. Several studies have tried the creation of data on living tissues for mechanical actions, which makes determining the mechanical characteristics of living tissues vital, but few have been commonly used. Therefore, we previously developed a sensing system that uses a hydraulic-driven micro mechanism to measure the force applied to an object when it is touched. Micro force sensors are necessary for various manipula-tions requiring careful operation. Unfortunately, the measurement accuracy of sensors tends to reduce with the reduction in sensor size. The proportional output in conventional force sensors, such as piezoelectric sensors, also decreases when the size of the sensor is reduced. However, a micro force sensor using a hydraulic-driven micro mechanism can obtain a large output even when it is small. Our system uses Pascal’s principle to measure small forces acting on the end effector. We propose methods for identifying the mechanical characteristics of certain viscoelastic materials similar to those used in a living organ. A hydraulic-driven micro device pushes an object and measures the reaction force and its displacement. We have used two types of micro devices, micro cylinder and micro bellows. Its stiffness and viscosity coefficient are obtained through calculations using Kelvin-Voigt and Zenner models. Discrete displacement and load data are applied to the estimated model, and the mechanical characteristics of the materials are identified as a minimized value between the estimated value and experimental one. We conducted experiments using the proposed identification methods on viscoelastic materials, and the results indicate that the value provided from the Kelvin-Voigt model was near the truth value.
AB - The medical and bio-engineering fields have been increasingly using information and communication technology. To introduce robots into surgical procedures, data on surgical operations are required. Several studies have tried the creation of data on living tissues for mechanical actions, which makes determining the mechanical characteristics of living tissues vital, but few have been commonly used. Therefore, we previously developed a sensing system that uses a hydraulic-driven micro mechanism to measure the force applied to an object when it is touched. Micro force sensors are necessary for various manipula-tions requiring careful operation. Unfortunately, the measurement accuracy of sensors tends to reduce with the reduction in sensor size. The proportional output in conventional force sensors, such as piezoelectric sensors, also decreases when the size of the sensor is reduced. However, a micro force sensor using a hydraulic-driven micro mechanism can obtain a large output even when it is small. Our system uses Pascal’s principle to measure small forces acting on the end effector. We propose methods for identifying the mechanical characteristics of certain viscoelastic materials similar to those used in a living organ. A hydraulic-driven micro device pushes an object and measures the reaction force and its displacement. We have used two types of micro devices, micro cylinder and micro bellows. Its stiffness and viscosity coefficient are obtained through calculations using Kelvin-Voigt and Zenner models. Discrete displacement and load data are applied to the estimated model, and the mechanical characteristics of the materials are identified as a minimized value between the estimated value and experimental one. We conducted experiments using the proposed identification methods on viscoelastic materials, and the results indicate that the value provided from the Kelvin-Voigt model was near the truth value.
KW - Accuracy
KW - Actuator
KW - Hydrostatic
KW - Sensor
UR - http://www.scopus.com/inward/record.url?scp=85088243008&partnerID=8YFLogxK
U2 - 10.20965/ijat.2020.p0625
DO - 10.20965/ijat.2020.p0625
M3 - 学術論文
AN - SCOPUS:85088243008
SN - 1881-7629
VL - 14
SP - 625
EP - 632
JO - International Journal of Automation Technology
JF - International Journal of Automation Technology
IS - 4
ER -