抄録
Background/Aim: To compare operative results between venous puncture (P) with real-time ultrasonography vs. cut-down (CD) with preoperative ultrasonography for totally implantable central vein access device (TICVAD) implantation performed by residents (R) vs. senior surgeons (S). Patients and Methods: Adult oncologic patients (n=268) undergoing TICVAD implantations were retrospectively compared between 172 Ps and 96 CDs. Then, we compared Ps performed by R (P-R, n=131) and S (P-S, n=41) and CDs performed by R (CD-R, n=59) and S (CD-S, n=37). Results: Median operation times were 40 min in the P group and 53.5 min in the CD group, and times were significantly shorter for P-S and CD-S. Completion rates were comparable for each method and each surgeon. Intraoperative complication rates were 3.8% (P-R), 2.4% (P-S), and 0% (CD-R and CD-S). Conclusion: P with real-time ultrasonography did not avoid complications compared to CD with preoperative ultrasonography. The latter performed safely even by residents.
本文言語 | 英語 |
---|---|
ページ(範囲) | 1197-1204 |
ページ数 | 8 |
ジャーナル | In Vivo |
巻 | 35 |
号 | 2 |
DOI | |
出版ステータス | 出版済み - 2021/03 |
ASJC Scopus 主題領域
- 生化学、遺伝学、分子生物学一般
- 薬理学