TY - JOUR
T1 - Uterine peristalsis
T2 - Comparison of transvaginal ultrasound and two different sequences of cine MR imaging
AU - Nakai, Asako
AU - Togashi, Kaori
AU - Kosaka, Kenzo
AU - Kido, Aki
AU - Hiraga, Akira
AU - Fujiwara, Toshitaka
AU - Koyama, Takashi
AU - Fujii, Shingo
PY - 2004
Y1 - 2004
N2 - Purpose: To compare uterine peristalsis as seen on two different magnetic resonance (MR) imaging sequences and transvaginal ultrasound (TVUS), so as to better determine the best method for evaluating uterine peristalsis. Materials and Methods: Eleven women in the periovulatory phase of the menstrual cycle underwent TVUS and cine MR imaging within a time period of three hours. Findings on cine MR images obtained with a serial 60 half-Fourier acquisition single-shot turbo spin-echo (HASTE) sequence and a 300 true fast imaging with steady-state precession (FISP) sequence were compared with TVUS. Results: The image quality of the HASTE technique was the best among the three methods, followed by TVUS, and then true FISP technique (P < 0.001). Uterine peristalsis was detected in 100% of subjects using HASTE, 82% with True FISP, and 100% with TVUS. With HASTE technique, true FISP, and TVUS, respectively, endometrial stripping movement was identified in 100%, 82%, and 100%; direction was identified in 100%, 45% (P = 0.014), and 73%; and wave conduction toward the outer myometrium was identified in 55%, 9% (P = 0.025), and 0% (P = 0.014). Conclusion: Cine MR imaging by HASTE technique with a time resolution of two seconds best delineated uterine peristalsis compared to that by true FISP technique or with TVUS.
AB - Purpose: To compare uterine peristalsis as seen on two different magnetic resonance (MR) imaging sequences and transvaginal ultrasound (TVUS), so as to better determine the best method for evaluating uterine peristalsis. Materials and Methods: Eleven women in the periovulatory phase of the menstrual cycle underwent TVUS and cine MR imaging within a time period of three hours. Findings on cine MR images obtained with a serial 60 half-Fourier acquisition single-shot turbo spin-echo (HASTE) sequence and a 300 true fast imaging with steady-state precession (FISP) sequence were compared with TVUS. Results: The image quality of the HASTE technique was the best among the three methods, followed by TVUS, and then true FISP technique (P < 0.001). Uterine peristalsis was detected in 100% of subjects using HASTE, 82% with True FISP, and 100% with TVUS. With HASTE technique, true FISP, and TVUS, respectively, endometrial stripping movement was identified in 100%, 82%, and 100%; direction was identified in 100%, 45% (P = 0.014), and 73%; and wave conduction toward the outer myometrium was identified in 55%, 9% (P = 0.025), and 0% (P = 0.014). Conclusion: Cine MR imaging by HASTE technique with a time resolution of two seconds best delineated uterine peristalsis compared to that by true FISP technique or with TVUS.
KW - Cine MRI
KW - Peristalsis
KW - Transvaginal ultrasound
KW - Uterine function
KW - Uterus
UR - http://www.scopus.com/inward/record.url?scp=4344578569&partnerID=8YFLogxK
U2 - 10.1002/jmri.20140
DO - 10.1002/jmri.20140
M3 - 学術論文
C2 - 15332254
AN - SCOPUS:4344578569
SN - 1053-1807
VL - 20
SP - 463
EP - 469
JO - Journal of Magnetic Resonance Imaging
JF - Journal of Magnetic Resonance Imaging
IS - 3
ER -