TY - JOUR
T1 - Simultaneous determination of alcohols including diols and triols by HPLC with ultraviolet detection based on the formation of a copper(II) complex
AU - Tanaka, Sohei
AU - Dohi, Takumi
AU - Aizawa, Sen Ichi
AU - Kemmei, Tomoko
AU - Terashima, Hiroyuki
AU - Taga, Atsushi
AU - Yamamoto, Atsushi
AU - Kodama, Shuji
N1 - Publisher Copyright:
© 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim
PY - 2017/11
Y1 - 2017/11
N2 - We developed a reversed-phase high-performance liquid chromatography method with ultraviolet detection using on-line complexation with Cu(II) ion for analysis of five alcohols including diols and triol (methanol, ethanol, 1,2-propanediol, 1,3-propanediol, and glycerol). The Cu(II) ion concentration in the mobile phase had a great influence on the peak areas of these alcohols, but not on their retention times. Column temperature (25−40°C) and pH of the mobile phase did not affect the separation of analytes. The optimum separation conditions were determined as 5 mM CuSO4, 3 mM H2SO4, and 3 mM NaOH at 30°C. The ratio of the peak areas for three alcohols (methanol, 1,2-propanediol, and glycerol) was in good agreement with that calculated from the obtained stability constants, molar absorption coefficients for the 1:1 Cu(II) complexes with the three alcohols, and the injected molar quantities. This fact strongly suggests that the observed high-performance liquid chromatography signals resulted from formation of the 1:1 Cu(II)–alcohol complexes. Using the proposed method, these five alcohols in spirit, liquid for electronic cigarette, mouthwash, and nail enamel remover samples were successfully analyzed with only a simple pretreatment.
AB - We developed a reversed-phase high-performance liquid chromatography method with ultraviolet detection using on-line complexation with Cu(II) ion for analysis of five alcohols including diols and triol (methanol, ethanol, 1,2-propanediol, 1,3-propanediol, and glycerol). The Cu(II) ion concentration in the mobile phase had a great influence on the peak areas of these alcohols, but not on their retention times. Column temperature (25−40°C) and pH of the mobile phase did not affect the separation of analytes. The optimum separation conditions were determined as 5 mM CuSO4, 3 mM H2SO4, and 3 mM NaOH at 30°C. The ratio of the peak areas for three alcohols (methanol, 1,2-propanediol, and glycerol) was in good agreement with that calculated from the obtained stability constants, molar absorption coefficients for the 1:1 Cu(II) complexes with the three alcohols, and the injected molar quantities. This fact strongly suggests that the observed high-performance liquid chromatography signals resulted from formation of the 1:1 Cu(II)–alcohol complexes. Using the proposed method, these five alcohols in spirit, liquid for electronic cigarette, mouthwash, and nail enamel remover samples were successfully analyzed with only a simple pretreatment.
KW - copper
KW - ethanol
KW - glycerol
KW - propanediol
KW - ultraviolet detection
UR - http://www.scopus.com/inward/record.url?scp=85030485677&partnerID=8YFLogxK
U2 - 10.1002/jssc.201700635
DO - 10.1002/jssc.201700635
M3 - 学術論文
C2 - 28851084
AN - SCOPUS:85030485677
SN - 1615-9306
VL - 40
SP - 4168
EP - 4175
JO - Journal of Separation Science
JF - Journal of Separation Science
IS - 21
ER -