T1 - Non-contrast-enhanced MR portography with balanced steady-state free-precession sequence and time-spatial labeling inversion pulses
T2 - Comparison of imaging with flow-in and flow-out methods
AU - Furuta, Akihiro
AU - Isoda, Hiroyoshi
AU - Yamashita, Rikiya
AU - Ohno, Tsuyoshi
AU - Kawahara, Seiya
AU - Shimizu, Hironori
AU - Fujimoto, Koji
AU - Kido, Aki
AU - Kusahara, Hiroshi
AU - Togashi, Kaori
PY - 2014/9
Y1 - 2014/9
N2 - Purpose To compare and evaluate images of non-contrast-enhanced MR portography acquired with two different methods, the flow-in and flow-out methods. Materials and Methods Twenty-five healthy volunteers were examined using respiratory-triggered three-dimensional balanced steady-state free-precession (SSFP) with two selective inversion recovery pulses (flow-in method) and one tagging pulse and one nonselective inversion recovery pulse (flow-out method). For quantitative analysis, vessel-to-liver contrast (Cv-l) ratios of the main portal vein (MPV), right portal vein (RPV), and left portal vein (LPV) were measured. The quality of portal vein visualization was scored using a four-point scale. Results The Cv-ls of the MPV, RPV, and LPV were all significantly higher with the flow-out than flow-in method (MPV = 0.834 ± 0.06 versus 0.711 ± 0.10; RPV = 0.861 ± 0.04 versus 0.729 ± 0.11; LPV = 0.786 ± 0.08 versus 0.545 ± 0.22; P < 0.0001). In all analyses of vessel visibility, non-contrast-enhanced MR portography with the flow-out method showed higher scores than with the flow-in method. With the flow-out method, visual scores of the MPV, RPV, portal vein branches of segments 4 (P4), and 8 (P8) were significantly better than with the flow-in method (MPV = 3.4 ± 0.7 versus 2.6 ± 0.9; RPV = 4.0 ± 0.0 versus 3.5 ± 0.9; P4 = 2.8 ± 1.3 versus 1.6 ± 1.0; P8 = 4.0 ± 0.0 versus 2.9 ± 1.1; P < 0.05). Conclusion Non-contrast-enhanced MR portography with the flow-out method improves the visualization of the intrahepatic portal vein in comparison with the flow-in method.
AB - Purpose To compare and evaluate images of non-contrast-enhanced MR portography acquired with two different methods, the flow-in and flow-out methods. Materials and Methods Twenty-five healthy volunteers were examined using respiratory-triggered three-dimensional balanced steady-state free-precession (SSFP) with two selective inversion recovery pulses (flow-in method) and one tagging pulse and one nonselective inversion recovery pulse (flow-out method). For quantitative analysis, vessel-to-liver contrast (Cv-l) ratios of the main portal vein (MPV), right portal vein (RPV), and left portal vein (LPV) were measured. The quality of portal vein visualization was scored using a four-point scale. Results The Cv-ls of the MPV, RPV, and LPV were all significantly higher with the flow-out than flow-in method (MPV = 0.834 ± 0.06 versus 0.711 ± 0.10; RPV = 0.861 ± 0.04 versus 0.729 ± 0.11; LPV = 0.786 ± 0.08 versus 0.545 ± 0.22; P < 0.0001). In all analyses of vessel visibility, non-contrast-enhanced MR portography with the flow-out method showed higher scores than with the flow-in method. With the flow-out method, visual scores of the MPV, RPV, portal vein branches of segments 4 (P4), and 8 (P8) were significantly better than with the flow-in method (MPV = 3.4 ± 0.7 versus 2.6 ± 0.9; RPV = 4.0 ± 0.0 versus 3.5 ± 0.9; P4 = 2.8 ± 1.3 versus 1.6 ± 1.0; P8 = 4.0 ± 0.0 versus 2.9 ± 1.1; P < 0.05). Conclusion Non-contrast-enhanced MR portography with the flow-out method improves the visualization of the intrahepatic portal vein in comparison with the flow-in method.
KW - MR angiography
KW - balanced SSFP
KW - flow-out method
KW - non-contrast-enhanced
KW - portal vein
KW - time-spatial labeling pulses
UR - http://www.scopus.com/inward/record.url?scp=84906090518&partnerID=8YFLogxK
U2 - 10.1002/jmri.24427
DO - 10.1002/jmri.24427
M3 - 学術論文
C2 - 24924213
AN - SCOPUS:84906090518
SN - 1053-1807
VL - 40
SP - 583
EP - 587
JO - Journal of Magnetic Resonance Imaging
JF - Journal of Magnetic Resonance Imaging
IS - 3
ER -