TY - JOUR
T1 - Internal evaluation of impregnation treatment of waterlogged wood; relation between concentration of internal materials and relaxation time using magnetic resonance imaging
AU - Kanazawa, Yuki
AU - Yamada, Tetsuya
AU - Kido, Aki
AU - Fujimoto, Koji
AU - Takakura, Kyoko
AU - Hayashi, Hiroaki
AU - Fushimi, Yasutaka
AU - Kozawa, Satoshi
AU - Koizumi, Koji
AU - Okuni, Makiko
AU - Ueda, Naomi
AU - Togashi, Kaori
N1 - Publisher Copyright:
© 2017 Elsevier Inc.
PY - 2017/5/1
Y1 - 2017/5/1
N2 - The purpose of this study is to clarify the degree of impregnation resulting from treatment of internal waterlogged wood samples using MRI. On a 1.5 T MR scanner, T1 and T2 measurements were performed using inversion recovery and spin-echo sequences, respectively. The samples were cut waterlogged pieces of wood treated with various impregnation techniques which were divided into different concentrations of trehalose (C12H22O11) and polyethylene glycol (PEG; HO-(C2H4O)n-H) solutions. Then these samples underwent impregnation treatment every two weeks. From the results, we found that the slope of the T1-concentration curve using linear fitting showed the value of the internal area for PEG to be higher than the external area; internal, − 2.73 ms/wt% (R2 = 0.880); external, − 1.50 ms/wt% (R2 = 0.887). Furthermore, the slope of the T1-concentration curve using linear fitting showed the values for trehalose to have almost no difference when comparing the internal and the external areas; internal, − 2.79 ms/wt% (R2 = 0.759); external, − 3.02 ms/wt% (R2 = 0.795). However, the slope of the T2-concentration curve using linear fitting for PEG showed that there was only a slight change between the internal and the external areas; internal, 0.26 ms/wt% (R2 = 0.642); external, 0.18 ms/wt% (R2 = 0.920). The slope of the T2-concentration curve did not show a change in linear relationship between the internal and the external areas; internal, 0.06 ms/wt% (R2 = 0.175); external, − 0.14 ms/wt% (R2 = 0.043). In conclusion, using visualization of relaxation time T1, it is possible to obtain more detail information noninvasively concerning the state of impregnation treatment of internal waterlogged wood.
AB - The purpose of this study is to clarify the degree of impregnation resulting from treatment of internal waterlogged wood samples using MRI. On a 1.5 T MR scanner, T1 and T2 measurements were performed using inversion recovery and spin-echo sequences, respectively. The samples were cut waterlogged pieces of wood treated with various impregnation techniques which were divided into different concentrations of trehalose (C12H22O11) and polyethylene glycol (PEG; HO-(C2H4O)n-H) solutions. Then these samples underwent impregnation treatment every two weeks. From the results, we found that the slope of the T1-concentration curve using linear fitting showed the value of the internal area for PEG to be higher than the external area; internal, − 2.73 ms/wt% (R2 = 0.880); external, − 1.50 ms/wt% (R2 = 0.887). Furthermore, the slope of the T1-concentration curve using linear fitting showed the values for trehalose to have almost no difference when comparing the internal and the external areas; internal, − 2.79 ms/wt% (R2 = 0.759); external, − 3.02 ms/wt% (R2 = 0.795). However, the slope of the T2-concentration curve using linear fitting for PEG showed that there was only a slight change between the internal and the external areas; internal, 0.26 ms/wt% (R2 = 0.642); external, 0.18 ms/wt% (R2 = 0.920). The slope of the T2-concentration curve did not show a change in linear relationship between the internal and the external areas; internal, 0.06 ms/wt% (R2 = 0.175); external, − 0.14 ms/wt% (R2 = 0.043). In conclusion, using visualization of relaxation time T1, it is possible to obtain more detail information noninvasively concerning the state of impregnation treatment of internal waterlogged wood.
KW - Conservation science
KW - Impregnation treatment
KW - Magnetic resonance imaging (MRI)
KW - Relaxation time
KW - Repair operation
KW - Waterlogged wood
UR - http://www.scopus.com/inward/record.url?scp=85010223589&partnerID=8YFLogxK
U2 - 10.1016/j.mri.2017.01.010
DO - 10.1016/j.mri.2017.01.010
M3 - 学術論文
C2 - 28095302
AN - SCOPUS:85010223589
SN - 0730-725X
VL - 38
SP - 196
EP - 201
JO - Magnetic Resonance Imaging
JF - Magnetic Resonance Imaging
ER -