Improvement of axial spatial resolution of ultrasound image using Wiener filter for measurement of intima-media thickness of carotid artery

Hideyuki Hasegawa, Sho Kageyama, Hiroshi Kanai

研究成果: 書籍の章/レポート/会議録会議への寄与査読

2 被引用数 (Scopus)

抄録

Measurement of intima-media thickness (IMT) of the carotid artery by ultrasonography is widely used for diagnosis of atherosclerosis. For accurate measurement of IMT, in the present study, a method based on the Wiener filter was developed for improvement of image spatial resolution. There are many studies on improvement of spatial resolution for elimination of the point spread function (PSF) of a system using a deconvolution filter. PSF is determined by the transfer function H() (including transfer function of ultrasonic probe and tissue attenuation property). In most of developed methods, PSF is separately measured using a target, such as a fine wire in water, prior to the actual in vivo measurement. However, it is difficult to predict the subject-dependent change in PSF owing to frequency-dependent attenuation by tissue. Therefore, conventional deconvolution filters do not work effectively. In the present study, the magnitude H() was estimated by averaging power spectra of RF echoes in all scan lines obtained from the actual in vivo measurement to consider frequency-dependent attenuation. Although there are many dips in the respective power spectra due to interference of echoes from many scatterers, such dips can be suppressed by averaging power spectra because locations of dips are different line by line owing to randomness of scatterer distribution. On the other hand, the phase of H() was estimated beforehand from the phase of frequency spectrum Y() of the transmitted ultrasound signal received by a hydrophone placed in water because attenuation by tissue does not affect the phase of the transfer function. The phase of squared Y() was used as the phase of H() by considering a pulse-echo measurement. From the estimated H(), a deconvolution filter was designed using the Wiener filter. Improvement of axial resolution was evaluated by measuring an echo from a fine wire placed in water. Axial resolution defined by the width at half maximum was improved from 0.2 mm to 0.12 mm. Furthermore, the proposed method was applied to RF echoes obtained from a carotid artery. The axial resolution was significantly improved compared with conventional B-mode image.

本文言語英語
ホスト出版物のタイトル2013 IEEE International Ultrasonics Symposium, IUS 2013
ページ1232-1235
ページ数4
DOI
出版ステータス出版済み - 2013
イベント2013 IEEE International Ultrasonics Symposium, IUS 2013 - Prague, チェコ共和国
継続期間: 2013/07/212013/07/25

出版物シリーズ

名前IEEE International Ultrasonics Symposium, IUS
ISSN(印刷版)1948-5719
ISSN(電子版)1948-5727

学会

学会2013 IEEE International Ultrasonics Symposium, IUS 2013
国/地域チェコ共和国
CityPrague
Period2013/07/212013/07/25

ASJC Scopus 主題領域

  • 音響学および超音波学

フィンガープリント

「Improvement of axial spatial resolution of ultrasound image using Wiener filter for measurement of intima-media thickness of carotid artery」の研究トピックを掘り下げます。これらがまとまってユニークなフィンガープリントを構成します。

引用スタイル