TY - JOUR
T1 - Evaluation of two-dimensional L-COSY and JPRESS using a 3 T MRI scanner
T2 - From phantoms to human brain in vivo
AU - Thomas, M. Albert
AU - Hattori, Noriaki
AU - Umeda, Masahiro
AU - Sawada, Tohru
AU - Naruse, Shoji
PY - 2003/8
Y1 - 2003/8
N2 - Localized versions of two-dimensional (2D) magnetic resonance spectroscopic (MRS) sequences, namely JPRESS and L-COSY, have been implemented on a whole-body 3T MRI/MRS scanner. Volume selection was achieved using three slice-selective radio-frequency (RF) pulses: 90°-180°-180° in JPRESS and 90°-180°-90° in L-COSY with a CHESS sequence prior to voxel localization for global water suppression. The last 180° RF pulse was used for resolving the J-coupled cross peaks in JPRESS, whereas the last 90° RF pulse was used for coherence transfer between J-coupled metabolites in L-COSY. A head MRI coil for 'transmission' and a 4 inch receive surface coil for 'reception' or a head coil transmit/receive were used. A total of 16 healthy volunteers were investigated using these 2D MRS sequences. Voxel sizes of 18 and 27 ml were localized in the occipito-parietal gray and white matter regions and the total duration for each 2D signal acquisition was typically 35 min. Compared with 2D L-COSY, reduced spectral width along the second spectral dimension and shorter 2D spectral acquisition were the major advantages of 2D JPRESS. In contrast, increased spectral width along the new spectral dimension in L-COSY resulted in an improved spectral dispersion enabling the detection of several brain metabolites at low concentrations that have not been resolved using the conventional one-dimensional (1D) MRS techniques. Due to increased sampling rate, severe loss of metabolite signals due to T2, during t1, was a major drawback of 2D JPRESS in vivo.
AB - Localized versions of two-dimensional (2D) magnetic resonance spectroscopic (MRS) sequences, namely JPRESS and L-COSY, have been implemented on a whole-body 3T MRI/MRS scanner. Volume selection was achieved using three slice-selective radio-frequency (RF) pulses: 90°-180°-180° in JPRESS and 90°-180°-90° in L-COSY with a CHESS sequence prior to voxel localization for global water suppression. The last 180° RF pulse was used for resolving the J-coupled cross peaks in JPRESS, whereas the last 90° RF pulse was used for coherence transfer between J-coupled metabolites in L-COSY. A head MRI coil for 'transmission' and a 4 inch receive surface coil for 'reception' or a head coil transmit/receive were used. A total of 16 healthy volunteers were investigated using these 2D MRS sequences. Voxel sizes of 18 and 27 ml were localized in the occipito-parietal gray and white matter regions and the total duration for each 2D signal acquisition was typically 35 min. Compared with 2D L-COSY, reduced spectral width along the second spectral dimension and shorter 2D spectral acquisition were the major advantages of 2D JPRESS. In contrast, increased spectral width along the new spectral dimension in L-COSY resulted in an improved spectral dispersion enabling the detection of several brain metabolites at low concentrations that have not been resolved using the conventional one-dimensional (1D) MRS techniques. Due to increased sampling rate, severe loss of metabolite signals due to T2, during t1, was a major drawback of 2D JPRESS in vivo.
KW - 2D correlated spectroscopy
KW - Cerebral Metabolites
KW - J-resolved spectroscopy
UR - http://www.scopus.com/inward/record.url?scp=0347504480&partnerID=8YFLogxK
U2 - 10.1002/nbm.825
DO - 10.1002/nbm.825
M3 - 学術論文
C2 - 14648883
AN - SCOPUS:0347504480
SN - 0952-3480
VL - 16
SP - 245
EP - 251
JO - NMR in Biomedicine
JF - NMR in Biomedicine
IS - 5
ER -