Endoscopic thyroidectomy using the EZ-VANS method

Takuya Nagata*, Yutaka Shimada, Takeshi Miwa, Isaya Hashimoto, Hirofumi Kojima, Tomoyuki Okumura, Kazuhiro Tsukada

*この論文の責任著者

研究成果: ジャーナルへの寄稿学術論文査読

5 被引用数 (Scopus)

抄録

Purpose: Several video-assisted and robotic surgery techniques have been reported for resection of the thyroid and parathyroid glands. Our institute has started performing endoscopic thyroidectomy using the Lap-protector and E·Z-access system, referred to as E·Z-access using videoassisted neck surgery (EZ-VANS). In this report, we evaluate the safety and efficacy of this technique. Methods: From January 2007 to September 2014, 110 patients underwent resection of a primary thyroid tumor, 73 who underwent a cervical collar incision (the Open group) and 37 underwent EZ-VANS (the EZ-VANS group). Results: The average operating time was 159 and 172 min in the Open group and EZ-VANS group, respectively; the amount of blood loss was 46.5 and 54.7 ml, respectively; and the length of hospital stay after surgery was 4.3 and 5.2 days, respectively, with no significant differences observed between the two groups. The learning curve for the EZ-VANS technique was shorter than for open surgery. Conclusions: We confirmed that the EZ-VANS technique is a safe and useful method for resection of benign and early malignant thyroid tumors.

本文言語英語
ページ(範囲)575-582
ページ数8
ジャーナルSurgery Today
46
5
DOI
出版ステータス出版済み - 2016/06/22

ASJC Scopus 主題領域

  • 外科

フィンガープリント

「Endoscopic thyroidectomy using the EZ-VANS method」の研究トピックを掘り下げます。これらがまとまってユニークなフィンガープリントを構成します。

引用スタイル