TY - JOUR
T1 - Echo motion imaging with adaptive clutter filter for assessment of cardiac blood flow
AU - Takahashi, Hiroki
AU - Hasegawa, Hideyuki
AU - Kanai, Hiroshi
N1 - Publisher Copyright:
© 2015 The Japan Society of Applied Physics.
PY - 2015/7/1
Y1 - 2015/7/1
N2 - Visualization of the vortex blood flow in the cardiac chamber is a potential diagnostic tool for the evaluation of cardiac function. In the present study, a method for automatic selection of the desirable cutoff frequency of a moving target indicator filter, namely, a clutter filter, was proposed in order to visualize complex blood flows by the ultrahigh-frame-rate imaging of echoes from blood particles while suppressing clutter echoes. In this method, the cutoff frequency was adaptively changed as a function of the velocity of the heart wall (clutter source) in each frame. The feasibility of the proposed method was examined through the measurement of a healthy volunteer using parallel receive beamforming with a single transmission of a non-steered diverging beam. Using the moving target indicator filter as above with the cutoff frequency determined by the proposed method, the vortex-like blood flow in the cardiac chamber was visualized as movements of echoes from blood particles at a very high frame rate of 6024 Hz while suppressing clutter echoes.
AB - Visualization of the vortex blood flow in the cardiac chamber is a potential diagnostic tool for the evaluation of cardiac function. In the present study, a method for automatic selection of the desirable cutoff frequency of a moving target indicator filter, namely, a clutter filter, was proposed in order to visualize complex blood flows by the ultrahigh-frame-rate imaging of echoes from blood particles while suppressing clutter echoes. In this method, the cutoff frequency was adaptively changed as a function of the velocity of the heart wall (clutter source) in each frame. The feasibility of the proposed method was examined through the measurement of a healthy volunteer using parallel receive beamforming with a single transmission of a non-steered diverging beam. Using the moving target indicator filter as above with the cutoff frequency determined by the proposed method, the vortex-like blood flow in the cardiac chamber was visualized as movements of echoes from blood particles at a very high frame rate of 6024 Hz while suppressing clutter echoes.
UR - http://www.scopus.com/inward/record.url?scp=84936751724&partnerID=8YFLogxK
U2 - 10.7567/JJAP.54.07HF09
DO - 10.7567/JJAP.54.07HF09
M3 - 学術論文
AN - SCOPUS:84936751724
SN - 0021-4922
VL - 54
JO - Japanese Journal of Applied Physics
JF - Japanese Journal of Applied Physics
IS - 7
M1 - 07HF09
ER -