Denoising of low dose CT images using mask non-harmonic analysis with edge-preservation segmentation and whitening filter

Kousei Uchikoshi, Masaya Hasegawa, Shigeki Hirobayashi*

*この論文の責任著者

研究成果: 書籍の章/レポート/会議録会議への寄与査読

3 被引用数 (Scopus)

抄録

Computed tomography (CT) imaging acquires patient images using radiation. However, scanning with high doses of radiation can pose a risk to health, because of radiation hazards. Although the risk to the human body during a CT scan can be reduced by reducing the amount of radiation, the quality of the acquired images may deteriorate. Recently, denoising methods using nonlocal means or block matching and 3D filtering were demonstrated to be effective for denoising CT images. These methods performed denoising by adapting to the noise level, according to the position of the image. However, CT images exhibit different magnitudes of noise at different spatial frequencies, as can be observed in their noise power spectrum. Therefore, a method operating in the frequency space, which can accurately model the CT noise and reduce it effectively, is necessary. In this paper, we present a CT denoising method based on edge-preservation segmentation and denoising using mask nonharmonic analysis (mask NHA). Mask NHA can accurately analyze frequencies with high resolutions when applied to the edge preservation area. By using a whitening filter, we provide noise reduction for specific CT noises and improve the image quality of low-dose CT images. A denoising simulation was performed on a standard-dose CT image to which CT noise was added and the performance of the proposed method was compared to that of conventional methods. The proposed method was found to improve the peak signal-To-noise ratio by 3 to 5 dB, compared to the conventional mask NHA.

本文言語英語
ホスト出版物のタイトルMultimodal Biomedical Imaging XIV
編集者Fred S. Azar, Xavier Intes, Qianqian Fang
出版社SPIE
ISBN(電子版)9781510623842
DOI
出版ステータス出版済み - 2019
イベントMultimodal Biomedical Imaging XIV 2019 - San Francisco, 米国
継続期間: 2019/02/022019/02/03

出版物シリーズ

名前Progress in Biomedical Optics and Imaging - Proceedings of SPIE
10871
ISSN(印刷版)1605-7422

学会

学会Multimodal Biomedical Imaging XIV 2019
国/地域米国
CitySan Francisco
Period2019/02/022019/02/03

ASJC Scopus 主題領域

  • 電子材料、光学材料、および磁性材料
  • 生体材料
  • 原子分子物理学および光学
  • 放射線学、核医学およびイメージング

フィンガープリント

「Denoising of low dose CT images using mask non-harmonic analysis with edge-preservation segmentation and whitening filter」の研究トピックを掘り下げます。これらがまとまってユニークなフィンガープリントを構成します。

引用スタイル