TY - JOUR
T1 - Decoupling between diastolic pulmonary artery pressure and pulmonary capillary wedge pressure as a prognostic factor after continuous flow ventricular assist device implantation
AU - Imamura, Teruhiko
AU - Chung, Ben
AU - Nguyen, Ann
AU - Rodgers, Daniel
AU - Sayer, Gabriel
AU - Adatya, Sirtaz
AU - Sarswat, Nitasha
AU - Kim, Gene
AU - Raikhelkar, Jayant
AU - Ota, Takeyohi
AU - Song, Tae
AU - Juricek, Colleen
AU - Kagan, Viktoriya
AU - Jeevanandam, Valluvan
AU - Mehra, Mandeep
AU - Burkhoff, Daniel
AU - Uriel, Nir
N1 - Publisher Copyright:
© 2017 American Heart Association, Inc.
PY - 2017/9/1
Y1 - 2017/9/1
N2 - BACKGROUND: A cohort of heart failure (HF) patients receiving left ventricular assist devices (LVADs) has decoupling of their diastolic pulmonary artery pressure and pulmonary capillary wedge pressure. However, the clinical implications of this decoupling remain unclear. METHODS AND RESULTS: In this prospective study, patients with LVADs underwent routine invasive hemodynamic ramp testing with right heart catheterization, during which LVAD speeds were adjusted. Inappropriate decoupling was defined as a >5 mm Hg difference between diastolic pulmonary artery pressure and pulmonary capillary wedge pressure. The primary outcomes of survival and heart failure readmission rates after ramp testing were assessed. Among 63 LVAD patients (60±12 years old and 25 female [40%]), 27 patients (43%) had inappropriate decoupling at their baseline speed. After adjustment of their rotation speed during ramp testing, 30 patients (48%) had inappropriate decoupling. Uni/multivariable Cox analyses demonstrated that decoupling was the only significant predictor for the composite end point of death and heart failure readmission during the 1 year following the ramp study (total of 18 events; hazards ratio, 1.09; 95% confidence interval, 1.04-1.24; P<0.05). Furthermore, normalization of decoupling (n=8) during ramp testing was significantly associated with higher 1-year heart failure readmission-free survival rate compared with the non-normalized group (n=19, 100% versus 53%; P=0.035). CONCLUSIONS: The presence of inappropriate decoupling was associated with worse outcomes in patients with LVADs. Prospective, large-scale multicenter studies to validate the result are warranted.
AB - BACKGROUND: A cohort of heart failure (HF) patients receiving left ventricular assist devices (LVADs) has decoupling of their diastolic pulmonary artery pressure and pulmonary capillary wedge pressure. However, the clinical implications of this decoupling remain unclear. METHODS AND RESULTS: In this prospective study, patients with LVADs underwent routine invasive hemodynamic ramp testing with right heart catheterization, during which LVAD speeds were adjusted. Inappropriate decoupling was defined as a >5 mm Hg difference between diastolic pulmonary artery pressure and pulmonary capillary wedge pressure. The primary outcomes of survival and heart failure readmission rates after ramp testing were assessed. Among 63 LVAD patients (60±12 years old and 25 female [40%]), 27 patients (43%) had inappropriate decoupling at their baseline speed. After adjustment of their rotation speed during ramp testing, 30 patients (48%) had inappropriate decoupling. Uni/multivariable Cox analyses demonstrated that decoupling was the only significant predictor for the composite end point of death and heart failure readmission during the 1 year following the ramp study (total of 18 events; hazards ratio, 1.09; 95% confidence interval, 1.04-1.24; P<0.05). Furthermore, normalization of decoupling (n=8) during ramp testing was significantly associated with higher 1-year heart failure readmission-free survival rate compared with the non-normalized group (n=19, 100% versus 53%; P=0.035). CONCLUSIONS: The presence of inappropriate decoupling was associated with worse outcomes in patients with LVADs. Prospective, large-scale multicenter studies to validate the result are warranted.
KW - Heart failure
KW - Hemodynamics
KW - Pulmonary artery
KW - Survival rate
UR - http://www.scopus.com/inward/record.url?scp=85030431977&partnerID=8YFLogxK
U2 - 10.1161/CIRCHEARTFAILURE.117.003882
DO - 10.1161/CIRCHEARTFAILURE.117.003882
M3 - 学術論文
C2 - 28912260
AN - SCOPUS:85030431977
SN - 1941-3289
VL - 10
JO - Circulation: Heart Failure
JF - Circulation: Heart Failure
IS - 9
M1 - e003882
ER -