Conduction effect of thermal radiation in a metal shield pipe in a cryostat for a cryogenic interferometric gravitational wave detector

Takayuki Tomaru*, Masao Tokunari, Kazuaki Kuroda, Takashi Uchiyama, Akira Okutomi, Masatake Ohashi, Hiroyuki Kirihara, Nobuhiro Kimura, Yoshio Saito, Nobuaki Sato, Takakazu Shintomi, Toshikazu Suzuki, Tomiyoshi Haruyama, Shinji Miyoki, Kazuhiro Yamamoto, Akira Yamamoto

*この論文の責任著者

研究成果: ジャーナルへの寄稿学術論文査読

13 被引用数 (Scopus)

抄録

A large heat load caused by thermal radiation through a metal shield pipe was observed in a cooling test of a cryostat for a prototype of a cryogenic interferometric gravitational wave detector. The heat load was approximately 1000 times larger than the value calculated by the Stefan-Boltzmann law. We studied this phenomenon by simulation and experiment and found that it was caused by the conduction of thermal radiation in a metal shield pipe.