Comparison of the diagnostic performance of tryptase and histamine for perioperative anaphylaxis: A multicenter prospective study

Takashi Haraguchi, Tatsuo Horiuchi, Tomonori Takazawa*, Kazuhiro Nagumo, Masaki Orihara, Shigeru Saito

*この論文の責任著者

研究成果: ジャーナルへの寄稿学術論文査読

3 被引用数 (Scopus)

抄録

Background: Diagnosing perioperative anaphylaxis (POA) is often challenging. Although a guideline recommends measuring tryptase rather than histamine, there is little evidence for this. We aimed to examine the diagnostic performance and appropriate timing of tryptase and histamine measurements for diagnosing anaphylaxis, and the association between Hypersensitivity Clinical Scoring Scheme (HCSS) scores and elevated biomarkers. Methods: We measured tryptase and histamine levels thrice: 30 min, 2 h, and at least 24 h after an anaphylactic event for patients with suspected anaphylaxis, and at the induction of general anesthesia and 30 min and 2 h after the start of surgery for control patients without a reaction. Absolute values and the magnitude and rate of change from baseline were evaluated. We determined the thresholds of tryptase and histamine levels with the best diagnostic performance and compared their performance. Results: Forty-five patients with perioperative anaphylaxis were included in this study. The control group included 30 patients with uneventful general anesthesia and 12 patients with a suspected but unconfirmed diagnosis of perioperative anaphylaxis. Comparison at the same measurement timings showed that tryptase generally had better diagnostic performance than histamine. Both showed better diagnostic performance when assessed using multiple measurements rather than a single measurement. The best diagnostic performance was seen with the percentage change in the higher tryptase value, whether measured at 30 min or 2 h after anaphylaxis onset, as compared to baseline. However, neither tryptase nor histamine levels correlated with HCSS scores. Conclusions: Overall, tryptase showed better diagnostic performance than histamine. When multiple tryptase measurements are possible, parameters calculated using two acute phase measurements and the baseline level have better diagnostic performance.

本文言語英語
ページ(範囲)573-579
ページ数7
ジャーナルAllergology International
73
4
DOI
出版ステータス出版済み - 2024/10

ASJC Scopus 主題領域

  • 免疫アレルギー学

フィンガープリント

「Comparison of the diagnostic performance of tryptase and histamine for perioperative anaphylaxis: A multicenter prospective study」の研究トピックを掘り下げます。これらがまとまってユニークなフィンガープリントを構成します。

引用スタイル