Bioelectrical Impedance Analysis (BIA) of the association of the Japanese Kampo concept "Suidoku" (fluid disturbance) and the body composition of women

Aya Murakami, Daisuke Kobayashi, Toshio Kubota, Niina Zukeyama, Haru Mukae, Norihiro Furusyo, Mosaburo Kainuma*, Takao Shimazoe

*この論文の責任著者

研究成果: ジャーナルへの寄稿学術論文査読

4 被引用数 (Scopus)

抄録

Background: In Japanese Kampo medical practice, suidoku (fluid disturbance) is one of the most important concepts for selecting the proper medication. Suidoku is an excessive or uneven distribution of fluid that is indicated by splashing sounds and pitting edema. However, few objective reports about suidoku have been published. Bioelectrical impedance analysis (BIA) uses resistance values obtained from weak electrical currents to estimate body composition, including intracellular and extracellular water and muscle and fat mass. In this study, we used BIA to search for objective factors that can discriminate the various types of suidoku. Methods: Two hundred twenty-nine patients who visited the Kampo Medicine Clinic of Kyushu University Hospital from June 2010 to August 2015 were divided into non-suidoku (n = 180, 80 male and 100 female), splashing sound (n = 32, 8 male and 24 female) and edema groups (n = 17, 5 male and 12 female). Body composition values were taken from the electronic medical records of InBody730 (a vertical, segmental, multi-frequency analyzer by InBody, Tokyo Japan) testing done at the initial visit. Various parameters of the body composition values of female in the non-suidoku and suidoku groups (splashing sound and edema groups) were compared: there were too few male patients to provide significance. Results: The age and body weight were significantly lower in the splashing sound group than in the non-suidoku group (p < 0.05). In contrast, the body weight of the edema group was significantly heavier than that of the non-suidoku group (p < 0.05). In ROC analysis, the percent Body Fat ≤ 27.8 %, Muscle Mass Index of the Trunk ≤ 6.5 kg/m2, VFA (Visceral fat area) ≤ 5.4 and BMI ≤ 19.2 kg/m2 were associated with splashing sound, and Muscle Mass Index of Legs ≥ 4.8 kg/m2 and BMI ≥ 21.4 kg/m2 were associated with edema. Conclusion: Our data suggest that the use of this type of BIA to estimate body composition would be a useful tool for the diagnosis of suidoku for women.

本文言語英語
論文番号405
ジャーナルBMC Complementary and Alternative Medicine
16
1
DOI
出版ステータス出版済み - 2016/10/22

ASJC Scopus 主題領域

  • 補完代替医療

フィンガープリント

「Bioelectrical Impedance Analysis (BIA) of the association of the Japanese Kampo concept "Suidoku" (fluid disturbance) and the body composition of women」の研究トピックを掘り下げます。これらがまとまってユニークなフィンガープリントを構成します。

引用スタイル