TY - GEN
T1 - Two-dimensional blood flow vectors obtained with bidirectional Doppler ultrasound
AU - Masuno, Genta
AU - Nagaoka, Ryo
AU - Omori, Aiko
AU - Ishikawa, Yasuo
AU - Akagawa, Osamu
AU - Arakawa, Mototaka
AU - Saijo, Yoshifumi
N1 - Publisher Copyright:
© 2014 IEEE.
PY - 2014/11/2
Y1 - 2014/11/2
N2 - Precise measurement of blood flow is important because blood flow closely correlates formation of thrombus and atherosclerotic plaque. Among clinically applied modalities for blood flow measurement, color Doppler ultrasound shows two-dimensional (2D) distribution of one-dimensional blood flow component along the ultrasound beam. In the present study, 2D blood flow vector is obtained with high temporal and bidirectional Doppler ultrasound technique. Linear array probe with the central frequency of 7.5 MHz and an ultrasound data acquisition system with 128 transmit and 128 receive channels were equipped. Frame rate of 5 kHz was achieved by parallel receive beam forming with a wide transmitted wave. The flow velocity was measured from two different angles by beam steering. The interval of two measurements was 0.8 msec and it was considered as almost one moment to obtain 2D blood flow vector. B-mode image and 2D blood flow vector of the pulsatile flow in a carotid artery model showed small vortex at the bifurcation area. The method was also applied for visualization of in vivo blood flow vector in human carotid arteries. 2D blood flow measurement may predict the risk area of thrombus and plaque formation induced by abnormal blood flow.
AB - Precise measurement of blood flow is important because blood flow closely correlates formation of thrombus and atherosclerotic plaque. Among clinically applied modalities for blood flow measurement, color Doppler ultrasound shows two-dimensional (2D) distribution of one-dimensional blood flow component along the ultrasound beam. In the present study, 2D blood flow vector is obtained with high temporal and bidirectional Doppler ultrasound technique. Linear array probe with the central frequency of 7.5 MHz and an ultrasound data acquisition system with 128 transmit and 128 receive channels were equipped. Frame rate of 5 kHz was achieved by parallel receive beam forming with a wide transmitted wave. The flow velocity was measured from two different angles by beam steering. The interval of two measurements was 0.8 msec and it was considered as almost one moment to obtain 2D blood flow vector. B-mode image and 2D blood flow vector of the pulsatile flow in a carotid artery model showed small vortex at the bifurcation area. The method was also applied for visualization of in vivo blood flow vector in human carotid arteries. 2D blood flow measurement may predict the risk area of thrombus and plaque formation induced by abnormal blood flow.
UR - http://www.scopus.com/inward/record.url?scp=84929493927&partnerID=8YFLogxK
U2 - 10.1109/EMBC.2014.6944770
DO - 10.1109/EMBC.2014.6944770
M3 - 会議への寄与
C2 - 25571138
AN - SCOPUS:84929493927
T3 - 2014 36th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBC 2014
SP - 5093
EP - 5096
BT - 2014 36th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBC 2014
PB - Institute of Electrical and Electronics Engineers Inc.
T2 - 2014 36th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBC 2014
Y2 - 26 August 2014 through 30 August 2014
ER -