TY - JOUR
T1 - The determination of zinc using flow injection and continuous flow analysis combined with a polymer inclusion film-coated column
T2 - Application to the determination of zinc in alloys and commercial lithium chloride
AU - Kagaya, Shigehiro
AU - Hida-Matsuda, Kizuku
AU - Tsuzaka, Syunki
AU - Minami, Chikako
AU - Gemmei-Ide, Makoto
AU - Cattrall, Robert W.
AU - Kolev, Spas D.
N1 - Publisher Copyright:
© 2023 Elsevier B.V.
PY - 2023/7/1
Y1 - 2023/7/1
N2 - A column coated with a polymer inclusion film (PIF) containing Aliquat 336 as carrier cast on glass beads packed in a glass tube is described for the separation, preconcentration, and determination of zinc(II) in flow injection analysis (FIA) and continuous flow analysis (CFA) systems. In the FIA method, 200 μL of a sample solution containing 2 mol/L lithium chloride is injected into a 2 mol/L lithium chloride stream. This converts zinc(II) ion into its anionic chlorocomplexes which are then extracted into the Aliquat 336-based PIF by anion exchange. The extracted zinc(II) is then back-extracted into a stream of 1 mol/L sodium nitrate solution and determined spectrophotometrically using 4-(2-pyridylazo)resorcinol as the color reagent. The limit of detection (LOD, S/N = 2) was determined as 0.017 mg/L. The usability of the PIF-based FIA method was demonstrated by the determination of zinc in alloys. The PIF-coated column was also employed successfully in the CFA determination of zinc(II) as an impurity in commercial lithium chloride samples. For this, 2 mol/L commercial lithium chloride solution was passed through the column for a predetermined time period followed by stripping in a stream of 1 mol/L sodium nitrate solution.
AB - A column coated with a polymer inclusion film (PIF) containing Aliquat 336 as carrier cast on glass beads packed in a glass tube is described for the separation, preconcentration, and determination of zinc(II) in flow injection analysis (FIA) and continuous flow analysis (CFA) systems. In the FIA method, 200 μL of a sample solution containing 2 mol/L lithium chloride is injected into a 2 mol/L lithium chloride stream. This converts zinc(II) ion into its anionic chlorocomplexes which are then extracted into the Aliquat 336-based PIF by anion exchange. The extracted zinc(II) is then back-extracted into a stream of 1 mol/L sodium nitrate solution and determined spectrophotometrically using 4-(2-pyridylazo)resorcinol as the color reagent. The limit of detection (LOD, S/N = 2) was determined as 0.017 mg/L. The usability of the PIF-based FIA method was demonstrated by the determination of zinc in alloys. The PIF-coated column was also employed successfully in the CFA determination of zinc(II) as an impurity in commercial lithium chloride samples. For this, 2 mol/L commercial lithium chloride solution was passed through the column for a predetermined time period followed by stripping in a stream of 1 mol/L sodium nitrate solution.
KW - Continuous flow analysis
KW - Flow injection analysis
KW - Lithium chloride
KW - Polymer inclusion film (PIF)-Coated column
KW - Zinc
KW - Zinc alloy
UR - http://www.scopus.com/inward/record.url?scp=85153255045&partnerID=8YFLogxK
U2 - 10.1016/j.talanta.2023.124545
DO - 10.1016/j.talanta.2023.124545
M3 - 学術論文
C2 - 37084602
AN - SCOPUS:85153255045
SN - 0039-9140
VL - 259
JO - Talanta
JF - Talanta
M1 - 124545
ER -