Optimization of non-contrast-enhanced MR angiography of the renal artery with three-dimensional balanced steady-state free-precession and time-spatial labeling inversion pulse (time-SLIP) at 3T MRI, in relation to age and blood velocity

Yasuhisa Kurata, Aki Kido*, Koji Fujimoto, Kayo Kiguchi, Kyoko Takakura, Yusaku Moribata, Fuki Shitano, Yuki Himoto, Yasutaka Fushimi, Tomohisa Okada, Kaori Togashi

*Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

7 Scopus citations

Abstract

Purpose: To determine the optimal inversion time (TI) value of three-dimensional (3D) balanced steady-state free-precession time-spatial labeling inversion pulse (time-SLIP) technique for visualization of the renal artery at 3T MRI, and to assess whether the optimal TI is affected by the subject’s age and blood velocity. Materials and methods: Forty-two healthy volunteers (range 20–67 years) were enrolled in the study and subjected to non-contrast-enhanced renal MR angiography. Five different TI values (1200, 1400, 1600, 1800, and 2000 ms) were selected for evaluation. For quantitative evaluation, the relative signal intensity (SI) of the main renal artery was compared with that of the renal medulla (Vessel-to-Kidney ratio; VKR). Blood velocity of the abdominal aorta was measured using 2D phase contrast technique. For qualitative evaluation, two radiologists scored the depiction of the renal pelvis and the quality of visualization of the renal artery. Results: VKR is the highest at TI = 1600 ms. A strong negative correlation between age and blood velocity was demonstrated. Regarding the qualitative evaluation, the overall image scores of renal arteries were the highest at a TI = 1800 ms for both readers. The optimal TI values in subjects below 50 years of age were 1600 and 1800 ms, whereas in subjects above 50 years of age, the optimal TI value was 1800 ms. Conclusion: The optimal TI value for the visualization of renal arteries using time-SLIP technique at 3T MRI was 1800 ms. Subjects’ age affected optimal TI and this is likely due to differences in the blood velocity of the abdominal aorta.

Original languageEnglish
Pages (from-to)119-126
Number of pages8
JournalAbdominal Radiology
Volume41
Issue number1
DOIs
StatePublished - 2016/01/01

Keywords

  • Blood velocity
  • Non-contrast-enhanced MR angiography
  • Renal artery
  • Time-spatial labeling inversion pulse (time-SLIP)

ASJC Scopus subject areas

  • Radiological and Ultrasound Technology
  • Radiology Nuclear Medicine and imaging
  • Gastroenterology
  • Urology

Fingerprint

Dive into the research topics of 'Optimization of non-contrast-enhanced MR angiography of the renal artery with three-dimensional balanced steady-state free-precession and time-spatial labeling inversion pulse (time-SLIP) at 3T MRI, in relation to age and blood velocity'. Together they form a unique fingerprint.

Cite this