Abstract
The integrated optical pH and oxygen sensor array on which pH and oxygen sensor spots whose diameter is 10μm were arranged alternately on one chip, was developed by using microcontact "double" printing. FITC based pH sensor and ruthenium complex based oxygen sensor was stamped onto a DLC sputtered slide glasses. After the printing of oxygen sensor spots, pH sensor spots were stamped between oxygen sensor spots by using the same PDMS stamp. The response was measured by using a micro array scanner. pH sensor spots responded to only pH changes and oxygen sensor spots responded to only oxygen concentration changes.
Original language | English |
---|---|
Pages | 949-951 |
Number of pages | 3 |
State | Published - 2008 |
Event | 12th International Conference on Miniaturized Systems for Chemistry and Life Sciences, MicroTAS 2008 - San Diego, CA, United States Duration: 2008/10/12 → 2008/10/16 |
Conference
Conference | 12th International Conference on Miniaturized Systems for Chemistry and Life Sciences, MicroTAS 2008 |
---|---|
Country/Territory | United States |
City | San Diego, CA |
Period | 2008/10/12 → 2008/10/16 |
Keywords
- Microcontact printing
- Oxygen sensor
- PH sensor
- Sensor array
ASJC Scopus subject areas
- Chemical Engineering (miscellaneous)
- Bioengineering