TY - JOUR
T1 - Evaluation of Triggered Electromyogram Monitoring during Insertion of Percutaneous Pedicle Screws
AU - Futakawa, Hayato
AU - Nogami, Shigeharu
AU - Seki, Shoji
AU - Kawaguchi, Yoshiharu
AU - Nakano, Masato
N1 - Publisher Copyright:
© 2022 by the authors. Licensee MDPI, Basel, Switzerland.
PY - 2022/3/1
Y1 - 2022/3/1
N2 - Objective: percutaneous pedicle screw (PPS) fixation has been widely used in minimally invasive spine stabilization. Triggered electromyogram (TrEMG) monitoring is performed to prevent PPS misplacement, but is not widely accepted. We have newly developed an insulating tap device to minimize the misplacement of PPS. Methods: TrEMG was measurable in insulation tap devices in 31 cases, and in non-insulating tap devices in 27 cases. Fluoroscopy was used to insert 194 PPS and 154 PPS, respectively. Based on the Rampersaud classification of postoperative computed tomography, we classified PPS insertion into four categories (Grade A as no violation, Grade D as more than 4 mm perforation). Results: Grade A was noted in 168 PPSs (86.6%) and Grade B to D in 26 PPSs in the insulation tap device group, and Grade A was noted in 129 PPSs (83.8%) and Grade B to D in 25 PPSs in the non-insulating tap device group, respectively. At a cutoff value of 11 mA, the sensitivity was 41.4% and the specificity was 98.2%. The sensitivity and specificity of the non-insulating tap device were 4.0% and 99.2%, respectively. Conclusions: The insulation treatment of the tap device has improved the sensitivity of TrEMG. TrEMG using the insulating tap device is one of the methods for safe PPS insertion.
AB - Objective: percutaneous pedicle screw (PPS) fixation has been widely used in minimally invasive spine stabilization. Triggered electromyogram (TrEMG) monitoring is performed to prevent PPS misplacement, but is not widely accepted. We have newly developed an insulating tap device to minimize the misplacement of PPS. Methods: TrEMG was measurable in insulation tap devices in 31 cases, and in non-insulating tap devices in 27 cases. Fluoroscopy was used to insert 194 PPS and 154 PPS, respectively. Based on the Rampersaud classification of postoperative computed tomography, we classified PPS insertion into four categories (Grade A as no violation, Grade D as more than 4 mm perforation). Results: Grade A was noted in 168 PPSs (86.6%) and Grade B to D in 26 PPSs in the insulation tap device group, and Grade A was noted in 129 PPSs (83.8%) and Grade B to D in 25 PPSs in the non-insulating tap device group, respectively. At a cutoff value of 11 mA, the sensitivity was 41.4% and the specificity was 98.2%. The sensitivity and specificity of the non-insulating tap device were 4.0% and 99.2%, respectively. Conclusions: The insulation treatment of the tap device has improved the sensitivity of TrEMG. TrEMG using the insulating tap device is one of the methods for safe PPS insertion.
KW - Complication
KW - Minimally invasive spine stabilization
KW - Minimally invasive surgery
KW - Percutaneous pedicle screw
KW - Spine surgery
KW - Triggered electromyogram monitoring
UR - http://www.scopus.com/inward/record.url?scp=85125042612&partnerID=8YFLogxK
U2 - 10.3390/jcm11051197
DO - 10.3390/jcm11051197
M3 - 学術論文
C2 - 35268288
AN - SCOPUS:85125042612
SN - 2077-0383
VL - 11
JO - Journal of Clinical Medicine
JF - Journal of Clinical Medicine
IS - 5
M1 - 1197
ER -