Dose assessment for patients with stage I non-small cell lung cancer receiving passive scattering carbon-ion radiotherapy using daily computed tomographic images: A prospective study

Yang Li, Yoshiki Kubota*, Nobuteru Kubo, Tatsuji Mizukami, Makoto Sakai, Hidemasa Kawamura, Daisuke Irie, Naoko Okano, Kazuhisa Tsuda, Akihiko Matsumura, Jun ichi Saitoh, Takashi Nakano, Tatsuya Ohno

*Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

12 Scopus citations

Abstract

Background and purpose: This study aimed to assess dose distributions for stage I non-small cell lung cancer (NSCLC) with passive scattering carbon-ion radiotherapy (C-ion RT) using daily computed tomography (CT) images. Materials and methods: We enrolled 10 patients with stage I NSCLC and acquired a total of 40 pre-fractional CT image series under the same settings as the planning CT images. These CT images were registered with planning CT images for dose evaluation using both bone matching (BM) and tumor matching (TM). Using deformable image registration, we generated accumulated doses. Moreover, the volumetric dose parameters were compared in terms of tumor coverage and lung exposure and statistical analyses were performed. Results: Overall, 25% of 40 fractional dose distributions were unacceptable with BM, compared with 2.5% with TM (P < 0.001). Using BM, three patients’ accumulated dose distributions were unacceptable; however, all were satisfactory with TM (P < 0.001). No differences were observed in water-equivalent path length (WEL). The required margins in patients with poor dose distribution were 5.9 and 4.4 mm for BM and TM, respectively. Conclusions: This study establishes that CT image-based TM is robust compared with conventional BM for both daily and accumulated dose distributions. The effects of changes in WEL seem to be limited. Hence, daily CT alignment is recommended for patients with stage I NSCLC receiving C-ion RT.

Original languageEnglish
Pages (from-to)224-230
Number of pages7
JournalRadiotherapy and Oncology
Volume144
DOIs
StatePublished - 2020/03

Keywords

  • Bone matching
  • Carbon-ion radiotherapy
  • Dose assessment
  • Lung cancer
  • Tumor matching

ASJC Scopus subject areas

  • Hematology
  • Oncology
  • Radiology Nuclear Medicine and imaging

Fingerprint

Dive into the research topics of 'Dose assessment for patients with stage I non-small cell lung cancer receiving passive scattering carbon-ion radiotherapy using daily computed tomographic images: A prospective study'. Together they form a unique fingerprint.

Cite this