T1 - Diaphragm Ultrasonography
T2 - Reference Values and Influencing Factors for Thickness, Thickening Fraction, and Excursion in the Seated Position
AU - Yamada, Toru
AU - Minami, Taro
AU - Yoshino, Syumpei
AU - Emoto, Ken
AU - Mabuchi, Suguru
AU - Hanazawa, Ryoichi
AU - Hirakawa, Akihiro
AU - Hashimoto, Masayoshi
N1 - Publisher Copyright:
© The Author(s) 2023.
PY - 2024/2
Y1 - 2024/2
N2 - Introduction: Measurements of diaphragm function by ultrasonography are affected by body position, but reference values in the seated position have not been established for an Asian population. This study aimed to determine reference values for diaphragm thickness, thickening fraction, and dome excursion by ultrasonography and to investigate the effects of sex, height, and body mass index. Methods: Diaphragm ultrasonography was performed on 109 seated Japanese volunteers with normal respiratory function who were enrolled between March 2022 and January 2023. Thickness, thickening fraction, and excursion were measured. Reference values and the measurement success rate were calculated. Multivariate analysis adjusted for sex, height, and body mass index was performed. Results: The measurement success rate was better for thickness than for excursion. The mean (lower limit of normal) values on the right/left sides were as follows. During quiet breathing, thickness at end expiration(mm) was 1.7 (0.9)/1.6 (0.80), thickening fraction(%) was 50 (0.0)/52 (0.0), and excursion(cm) was 1.7 (0.5)/1.9 (0.5). During deep breathing, the thickening fraction was 111 (24)/107 (22), and the excursion was 4.4 (1.7)/4.1 (2.0). In multivariate analysis, body mass index was positively associated with thickness but not with the thickening fraction. Conclusion: The reference values in this study were smaller than those in previous reports from Europe. Considering that thickness is influenced by body mass index, using Western reference values in Asia, where the average body mass index is lower, might not be appropriate. The thickening fraction in deep breathing is unaffected by other items and can be used more universally.
AB - Introduction: Measurements of diaphragm function by ultrasonography are affected by body position, but reference values in the seated position have not been established for an Asian population. This study aimed to determine reference values for diaphragm thickness, thickening fraction, and dome excursion by ultrasonography and to investigate the effects of sex, height, and body mass index. Methods: Diaphragm ultrasonography was performed on 109 seated Japanese volunteers with normal respiratory function who were enrolled between March 2022 and January 2023. Thickness, thickening fraction, and excursion were measured. Reference values and the measurement success rate were calculated. Multivariate analysis adjusted for sex, height, and body mass index was performed. Results: The measurement success rate was better for thickness than for excursion. The mean (lower limit of normal) values on the right/left sides were as follows. During quiet breathing, thickness at end expiration(mm) was 1.7 (0.9)/1.6 (0.80), thickening fraction(%) was 50 (0.0)/52 (0.0), and excursion(cm) was 1.7 (0.5)/1.9 (0.5). During deep breathing, the thickening fraction was 111 (24)/107 (22), and the excursion was 4.4 (1.7)/4.1 (2.0). In multivariate analysis, body mass index was positively associated with thickness but not with the thickening fraction. Conclusion: The reference values in this study were smaller than those in previous reports from Europe. Considering that thickness is influenced by body mass index, using Western reference values in Asia, where the average body mass index is lower, might not be appropriate. The thickening fraction in deep breathing is unaffected by other items and can be used more universally.
KW - Diaphragm
KW - Reference Values
KW - Seated Position
KW - Ultrasonography
UR - http://www.scopus.com/inward/record.url?scp=85178194889&partnerID=8YFLogxK
U2 - 10.1007/s00408-023-00662-2
DO - 10.1007/s00408-023-00662-2
M3 - 学術論文
C2 - 38019290
AN - SCOPUS:85178194889
SN - 0341-2040
VL - 202
SP - 83
EP - 90
JO - Lung
JF - Lung
IS - 1
ER -