TY - JOUR
T1 - Comparative Study of Three Commercial Blood (1→3)-β-D-glucan Detection Reagents for Invasive Mycosis
AU - Miyajima, Yuki
AU - Nagaoka, Kentaro
AU - Takegoshi, Yusuke
AU - Kaneda, Makito
AU - Murai, Yushi
AU - Kimoto, Kou
AU - Kawamura, Takayuki
AU - Ueno, Akitoshi
AU - Kawasuji, Hitoshi
AU - Kawago, Koyomi
AU - Fukui, Yasutaka
AU - Sakamaki, Ippei
AU - Yamamoto, Yoshihiro
N1 - Publisher Copyright:
© 2023, Japanese Society for Medical Mycology. All rights reserved.
PY - 2023
Y1 - 2023
N2 - Background: β-D-glucan detection is a useful diagnostic indicator of invasive mycosis. However, the differences among the commercial β-D-glucan assays are unclear. Herein, we explored the diagnostic value of various β-D-glucan assay reagents. Methods: This prospective observational study involved 175 eligible patients suspected to have fungal infections. For all participants, culture examinations were conducted with specimens obtained from the infected site (or blood culture), and β-Dglucan was measured using three commercial kits: Wako β-glucan test (Wako), Fungitech G-test MKII “Nissui” (MKII), and Fungitech G-test ES “Nissui” (ES). Results: A total of 163 participants were included. Among them, 32 cases of invasive mycosis, 34 cases with mycotic colonization infection, and 97 cases with non-fungal infections were confirmed. Regarding the diagnostic value of the commercial kits for invasive mycosis, the areas under the receiver operating characteristic curves were > 0.8 for all the agents. However, on the basis of the cut-off value set by the manufacturer, the sensitivity and specificity of the three kits for definitive invasive infection were 80.0% and 90.6% with Wako, 80.0% and 80.7% with MKII, and 86.7% and 71.8% with ES, respectively. Moreover, the rate of false-positive β-D-glucan elevation detection in patients with negative fungal culture was 9.3% with Wako, 18.6% with MKII, and 23.7% with ES. Conclusion: Despite the high diagnostic value of β-D-glucan detection in invasive fungal infections, caution should be exercised in interpreting the value of the assay reagents.
AB - Background: β-D-glucan detection is a useful diagnostic indicator of invasive mycosis. However, the differences among the commercial β-D-glucan assays are unclear. Herein, we explored the diagnostic value of various β-D-glucan assay reagents. Methods: This prospective observational study involved 175 eligible patients suspected to have fungal infections. For all participants, culture examinations were conducted with specimens obtained from the infected site (or blood culture), and β-Dglucan was measured using three commercial kits: Wako β-glucan test (Wako), Fungitech G-test MKII “Nissui” (MKII), and Fungitech G-test ES “Nissui” (ES). Results: A total of 163 participants were included. Among them, 32 cases of invasive mycosis, 34 cases with mycotic colonization infection, and 97 cases with non-fungal infections were confirmed. Regarding the diagnostic value of the commercial kits for invasive mycosis, the areas under the receiver operating characteristic curves were > 0.8 for all the agents. However, on the basis of the cut-off value set by the manufacturer, the sensitivity and specificity of the three kits for definitive invasive infection were 80.0% and 90.6% with Wako, 80.0% and 80.7% with MKII, and 86.7% and 71.8% with ES, respectively. Moreover, the rate of false-positive β-D-glucan elevation detection in patients with negative fungal culture was 9.3% with Wako, 18.6% with MKII, and 23.7% with ES. Conclusion: Despite the high diagnostic value of β-D-glucan detection in invasive fungal infections, caution should be exercised in interpreting the value of the assay reagents.
KW - (1→3)-β-D-glucan
KW - deep mycosis
UR - http://www.scopus.com/inward/record.url?scp=85149217935&partnerID=8YFLogxK
U2 - 10.3314/mmj.22-00016
DO - 10.3314/mmj.22-00016
M3 - 学術論文
C2 - 36858628
AN - SCOPUS:85149217935
SN - 2185-6486
VL - 64
SP - 1
EP - 6
JO - Medical Mycology Journal
JF - Medical Mycology Journal
IS - 1
ER -