TY - JOUR
T1 - Comparative analysis of different enzyme immunoassays for assessment of phosphatidylserine-dependent antiprothrombin antibodies
AU - Amengual, Olga
AU - Horita, Tetsuya
AU - Binder, Walter
AU - Norman, Gary L.
AU - Shums, Zakera
AU - Kato, Masaru
AU - Otomo, Kotaro
AU - Fujieda, Yuichiro
AU - Oku, Kenji
AU - Bohgaki, Toshiyuki
AU - Yasuda, Shinsuke
AU - Atsumi, Tatsuya
PY - 2014/9
Y1 - 2014/9
N2 - Phosphatidylserine-dependent antiprothrombin antibodies (aPS/PT) were strongly correlated with the presence of lupus anticoagulant showing a high specificity for the diagnosis of antiphospholipid syndrome. However, the main criticism for the clinical applicability of aPS/PT testing is the lack of reproducibility of the results among laboratories. In this study, we measured IgG and IgM aPS/PT using our original in-house enzyme-linked immunosorbent assays (ELISA) and commercial ELISA kits to assess the assay performance and to evaluate the accuracy of aPS/PT results. The study included 111 plasma samples collected from patients and stored at our laboratory for aPS/PT assessment. Sixty-one samples were tested for IgG aPS/PT using two assays: (1) aPS/PT in-house ELISA and (2) QUANTA Lite™ aPS/PT IgG ELISA kit (INOVA Diagnostics, Inc., USA). Fifty samples were evaluated for IgM aPS/PT using two assays: (1) aPS/PT in-house ELISA and (2) QUANTA Lite™ aPS/PT IgM ELISA kit (INOVA Diagnostics). Ninety-eight percent of samples yielded concordant results for IgG aPS/PT and 82 % for IgM aPS/PT. There was an excellent agreement between the IgG aPS/PT assays (Cohen κ = 0.962) and moderate agreement between the IgM aPS/PT assays (κ = 0.597). Statistically significant correlations in the aPS/PT results were obtained from both IgG and IgM aPS/PT assays (r = 0.749, r = 0.622, p < 0.001, respectively). In conclusion, IgG and IgM detection by ELISA is accurate. The performance of aPS/PT is reliable, and concordant results can be obtained using different ELISA methods.
AB - Phosphatidylserine-dependent antiprothrombin antibodies (aPS/PT) were strongly correlated with the presence of lupus anticoagulant showing a high specificity for the diagnosis of antiphospholipid syndrome. However, the main criticism for the clinical applicability of aPS/PT testing is the lack of reproducibility of the results among laboratories. In this study, we measured IgG and IgM aPS/PT using our original in-house enzyme-linked immunosorbent assays (ELISA) and commercial ELISA kits to assess the assay performance and to evaluate the accuracy of aPS/PT results. The study included 111 plasma samples collected from patients and stored at our laboratory for aPS/PT assessment. Sixty-one samples were tested for IgG aPS/PT using two assays: (1) aPS/PT in-house ELISA and (2) QUANTA Lite™ aPS/PT IgG ELISA kit (INOVA Diagnostics, Inc., USA). Fifty samples were evaluated for IgM aPS/PT using two assays: (1) aPS/PT in-house ELISA and (2) QUANTA Lite™ aPS/PT IgM ELISA kit (INOVA Diagnostics). Ninety-eight percent of samples yielded concordant results for IgG aPS/PT and 82 % for IgM aPS/PT. There was an excellent agreement between the IgG aPS/PT assays (Cohen κ = 0.962) and moderate agreement between the IgM aPS/PT assays (κ = 0.597). Statistically significant correlations in the aPS/PT results were obtained from both IgG and IgM aPS/PT assays (r = 0.749, r = 0.622, p < 0.001, respectively). In conclusion, IgG and IgM detection by ELISA is accurate. The performance of aPS/PT is reliable, and concordant results can be obtained using different ELISA methods.
KW - Antiphospholipid antibodies
KW - Antiphospholipid syndrome
KW - Lupus anticoagulant
KW - Thrombosis
UR - http://www.scopus.com/inward/record.url?scp=84906933972&partnerID=8YFLogxK
U2 - 10.1007/s00296-014-2951-0
DO - 10.1007/s00296-014-2951-0
M3 - 学術論文
C2 - 24497039
AN - SCOPUS:84906933972
SN - 0172-8172
VL - 34
SP - 1225
EP - 1230
JO - Rheumatology International
JF - Rheumatology International
IS - 9
ER -