A new technique for MR elastography of the supraspinatus muscle: A gradient-echo type multi-echo sequence

Daiki Ito, Tomokazu Numano*, Kazuyuki Mizuhara, Koichi Takamoto, Takaaki Onishi, Hisao Nishijo

*Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

16 Scopus citations

Abstract

Magnetic resonance elastography (MRE) can measure tissue stiffness quantitatively and noninvasively. Supraspinatus muscle injury is a significant problem among throwing athletes. The purpose of this study was to develop an MRE technique for application to the supraspinatus muscle by using a conventional magnetic resonance imaging (MRI). MRE acquisitions were performed with a gradient-echo type multi-echo MR sequence at 100 Hz pneumatic vibration. A custom-designed vibration pad was used as a pneumatic transducer in order to adapt to individual shoulder shapes. In a gradient-echo type multi-echo MR sequence, without motion encoding gradient (MEG) that synchronizes with vibrations, bipolar readout gradient lobes achieved a similar function to MEG (MEG-like effect). In other words, a dedicated MRE sequence (built-in MEG) is not always necessary for MRE. In this study, 7 healthy volunteers underwent MRE. We investigated the effects of direction of the MEG-like effect and selected imaging planes on the patterns of wave propagation (wave image). The results indicated that wave images showed clear wave propagation on a condition that the direction of the MEG-like effect was nearly perpendicular to the long axis of the supraspinatus muscle, and that the imaging plane was superior to the proximal supraspinatus muscle. This limited condition might be ascribed to specific features of fibers in the supraspinatus muscle and wave reflection from the boundaries of the supraspinous fossa. The mean stiffness of the supraspinatus muscle was 10.6 ± 3.17 kPa. Our results demonstrated that using MRE, our method can be applied to the supraspinatus muscle by using conventional MRI.

Original languageEnglish
Pages (from-to)1181-1188
Number of pages8
JournalMagnetic Resonance Imaging
Volume34
Issue number8
DOIs
StatePublished - 2016/10/01

Keywords

  • MR elastography
  • Muscle
  • Muscle fiber
  • Shoulder
  • Stiffness
  • Supraspinatus

ASJC Scopus subject areas

  • Biophysics
  • Biomedical Engineering
  • Radiology Nuclear Medicine and imaging

Fingerprint

Dive into the research topics of 'A new technique for MR elastography of the supraspinatus muscle: A gradient-echo type multi-echo sequence'. Together they form a unique fingerprint.

Cite this